iiDaemonInterval | input | integer | The number of seconds the daemon waits before he tries to check for new work, after it did not find something in the normal loop. |
icDaemonLogin | input | character | The login id that should be used by this daemon |
icDaemonPassword | input | character | The daemon password that should be used. If the client cannot use the progress "encode" function, the password should be passed "un-encoded", preceded by "TO-ENCODE". |
icDaemonLogFile | input | character | DaemonLogFile |
iiDaemonLogLevel | input | integer | DaemonLogLevel: The level of logging that should be done by the daemon. |
oiReturnStatus | output | integer | Return status of the method. |
/* ========================= */ /* Set default return-status */ /* ========================= */ assign oiReturnStatus = -98. /* =========================== */ /* Load / Create Dameon-record */ /* =========================== */ <Q-2 run DaemonPrim (all) (Read) (NoCache) (input {&SCANDAEMON}, (DaemonName) input ?, (DaemonId) output dataset tqDaemonPrim) in BBaseDaemon > find first tqDaemonPrim no-error. if available tqDaemonPrim then do : <M-11 run DataLoad (input '' (icRowids), input string(tqDaemonPrim.tiDaemonId) (icPkeys), input '' (icObjectIds), input '' (icFreeform), input false (ilKeepPrevious), output viFcReturnSuper (oiReturnStatus)) in BScanDaemon> if viFcReturnSuper <> 0 then do: assign oiReturnStatus = viFcReturnSuper. if oiReturnStatus < 0 then return. end. /* if viFcReturnSuper <> 0 */ find first tfcDaemon no-error. if not available tfcDaemon then do : assign oiReturnStatus = -3 vcMsgScan = trim(substitute(#T-9'Internal error: unable to load the Scan daemon based on its ID (&1).':255(384)T-9#,trim(string(tqDaemonPrim.tiDaemonId)))). <M-3 run SetMessage (input vcMsgScan (icMessage), input '':U (icArguments), input '':U (icFieldName), input '':U (icFieldValue), input 'E':U (icType), input 3 (iiSeverity), input '':U (icRowid), input 'BLF-190':U (icFcMsgNumber), input '' (icFcExplanation), input '' (icFcIdentification), input '' (icFcContext), output viFcReturnSuper (oiReturnStatus)) in BScanDaemon> Return. end. /* if not available tfcDaemon */ assign tfcDaemon.tc_Status = "C":U. end. /* if available tqDaemonPrim */ else do : <M-4 run DataNew (output viFcReturnSuper (oiReturnStatus)) in BScanDaemon> find first tfcDaemon no-error. if not available tfcDaemon then do : assign oiReturnStatus = -3 vcMsgScan = trim(#T-10'Internal error: unable to create Scan daemon.':255(385)T-10#). <M-5 run SetMessage (input vcMsgScan (icMessage), input '':U (icArguments), input '':U (icFieldName), input '':U (icFieldValue), input 'E':U (icType), input 3 (iiSeverity), input '':U (icRowid), input 'BLF-191':U (icFcMsgNumber), input '' (icFcExplanation), input '' (icFcIdentification), input '' (icFcContext), output viFcReturnSuper (oiReturnStatus)) in BScanDaemon> Return. end. /* if not available tfcDaemon */ end. /* Not if available tqDaemonPrim */ /* ===================================== */ /* Update the content of the Scan-daemon */ /* ===================================== */ assign tfcDaemon.DaemonInterval = (if iiDaemonInterval = 0 or iiDaemonInterval = ? then tfcDaemon.DaemonInterval else iiDaemonInterval) tfcDaemon.DaemonLogin = (if icDaemonLogin = "":U then tfcDaemon.DaemonLogin else icDaemonLogin) tfcDaemon.DaemonPassword = (if icDaemonPassword = "":U then tfcDaemon.DaemonPassword else icDaemonPassword) tfcDaemon.DaemonLogFile = (if icDaemonLogFile = "":U then tfcDaemon.DaemonLogFile else icDaemonLogFile) tfcDaemon.DaemonLogLevel = (if iiDaemonLogLevel = 0 then tfcDaemon.DaemonLogLevel else iiDaemonLogLevel). /* ==================================== */ /* Validate, AdditionalUpdates and Save */ /* ==================================== */ <M-6 run ValidateBC (output viFcReturnSuper (oiReturnStatus)) in BScanDaemon> if viFcReturnSuper <> 0 then do: assign oiReturnStatus = viFcReturnSuper. if oiReturnStatus < 0 then return. end. /* if viFcReturnSuper <> 0 */ <M-7 run AdditionalUpdates (output viFcReturnSuper (oiReturnStatus)) in BScanDaemon> if viFcReturnSuper <> 0 then do: assign oiReturnStatus = viFcReturnSuper. if oiReturnStatus < 0 then return. end. /* if viFcReturnSuper <> 0 */ <M-8 run DataSave (output viFcReturnSuper (oiReturnStatus)) in BScanDaemon> if viFcReturnSuper <> 0 then do: assign oiReturnStatus = viFcReturnSuper. if oiReturnStatus < 0 then return. end. /* if viFcReturnSuper <> 0 */ /* ========================= */ /* Set return-status = OK */ /* ========================= */ if oiReturnStatus = -98 then assign oiReturnStatus = 0.
define temp-table ttContext no-undo field propertyQualifier as character field propertyName as character field propertyValue as character index entityContext is primary unique propertyQualifier propertyName index propertyQualifier propertyQualifier. define dataset dsContext for ttContext. define variable vhContextDS as handle no-undo. define variable vhExceptionDS as handle no-undo. define variable vhServer as handle no-undo. define variable vhInputDS as handle no-undo. define variable vhInputOutputDS as handle no-undo. define variable vhOutputDS as handle no-undo. define variable vhParameter as handle no-undo. /* Create context */ create ttContext. assign ttContext.propertyName = "programName" ttContext.propertyValue = "BScanDaemon". create ttContext. assign ttContext.propertyName = "methodName" ttContext.propertyValue = "ApiUpdateDaemonConfiguration". create ttContext. assign ttContext.propertyName = "applicationId" ttContext.propertyValue = "fin". create ttContext. assign ttContext.propertyName = "entity" ttContext.propertyValue = "1000". create ttContext. assign ttContext.propertyName = "userName" ttContext.propertyValue = "mfg". create ttContext. assign ttContext.propertyName = "password" ttContext.propertyValue = "". /* Create input dataset */ create dataset vhInputDS. vhInputDS:read-xmlschema("file", "xml/bscandaemon.apiupdatedaemonconfiguration.i.xsd", ?). vhParameter = vhInputDS:get-buffer-handle("tParameterI"). vhParameter:buffer-create(). assign vhParameter::iiDaemonInterval = <parameter value> vhParameter::icDaemonLogin = <parameter value> vhParameter::icDaemonPassword = <parameter value> vhParameter::icDaemonLogFile = <parameter value> vhParameter::iiDaemonLogLevel = <parameter value>. /* Connect the AppServer */ create server vhServer. vhServer:connect("-URL <appserver-url>"). if not vhServer:connected() then do: message "Could not connect AppServer" view-as alert-box error title "Error". return. end. /* Run */ assign vhContextDS = dataset dsContext:handle. run program/rpcrequestservice.p on vhServer (input-output dataset-handle vhContextDS by-reference, output dataset-handle vhExceptionDS, input dataset-handle vhInputDS by-reference, input-output dataset-handle vhInputOutputDS by-reference, output dataset-handle vhOutputDS). /* Handle output however you want, in this example, we dump it to xml */ if valid-handle(vhExceptionDS) then vhExceptionDS:write-xml("file", "Exceptions.xml", true). if valid-handle(vhOutputDS) then vhOutputDS:write-xml("file", "Output.xml", true). /* Cleanup */ vhServer:disconnect(). assign vhServer = ?. if valid-handle(vhInputDS) then delete object vhInputDS. if valid-handle(vhOutputDS) then delete object vhOutputDS. if valid-handle(vhExceptionDS) then delete object vhExceptionDS.